Range Hood CFM & Makeup-Air Code in Houston

Upgrading to a bigger range hood is one of the most common choices in a kitchen remodel — and Houston code has a specific rule that kicks in once that hood is rated 400 cfm or more. Here is exactly what the code requires, how hoods are actually sized, and the duct rules that come with it.

Book a Kitchen Remodel ConsultationCall (832) 532-6829
Range hood Exhaust duct — outdoors Makeup-air inlet + damper
Illustration. A range hood duct terminates outdoors through a roof or wall cap, with a separate makeup-air inlet and damper supplying replacement air near the floor.
400 cfm
Exhaust capacity that triggers the makeup-air requirement, Houston Residential Code §M1503.6
≈1 cfm/100 BTU
Common industry rule of thumb for sizing a range hood to burner output
600–900 cfm
Typical rating for a 48" pro-style gas range (60,000–90,000 BTU) — well past the code trigger

Source: Houston Residential Code 2021, Chapter 15 (Exhaust Systems) and cross-corroborated range-hood sizing guides (checked Oct 22, 2026).

Will your new hood need makeup air?

Sizing the hood and triggering the makeup-air rule are two different questions. A bigger hood clears smoke and steam faster, but once it crosses 400 cfm, code may require a separate system just to replace the air it’s removing.

Interactive check
Check your range hood against the makeup-air rule

Pick what best describes your kitchen and hood:

No makeup-air trigger. §M1503.6 only applies above 400 cfm — but the duct still needs its own backdraft damper, correct material, and an independent run to the outdoors under §M1503.3/§M1503.4.
Makeup air is required. §M1503.6 calls for makeup air at a rate approximately equal to the exhaust rate, with a damper that opens automatically when the hood runs.
The written trigger condition isn’t met. Confirm this reading with your contractor or the Houston Permitting Center before skipping makeup air on a high-CFM hood — appliance venting changes are common during a remodel.
Different exception. §M1503.6 doesn’t apply because nothing is being exhausted outdoors — but a recirculating hood also can’t remove combustion byproducts or excess moisture the way a ducted hood can.

This helper summarizes Houston’s published code text and is not a code determination for your specific kitchen. Confirm with MAV or the City before work starts.

In the code’s own words

Rather than paraphrase, here is the Houston Residential Code’s own text:

“…each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) shall be mechanically or passively provided with makeup air at a rate approximately equal to the exhaust air rate.”
“Each damper shall be a gravity damper or an electrically operated damper that automatically opens when the exhaust system operates.”
30″300–600 cfm 36″450–600 cfm 48″ pro600–900 cfm 60″ pro900–1,200 cfm 400 cfm
Illustration. Typical range hood CFM sizing bands by width, using the ~1 CFM per 100 BTU industry rule of thumb. The 400 cfm code-trigger line falls well below most 48″ and 60″ pro-style ranges.
Makeup-air code trigger vs. typical range-hood CFM by width
Makeup-air code trigger (any hood): 400 cfmMakeup-air code trigger (any hood)400 cfm36" gas range, low end: 450 cfm36" gas range, low end450 cfm48" pro-style range, low end: 600 cfm48" pro-style range, low end600 cfm60" pro-style range, low end: 900 cfm60" pro-style range, low end900 cfm
+View as table
ItemValue (cfm)
Makeup-air code trigger (any hood)400
36″ gas range, low end450
48″ pro-style range, low end600
60″ pro-style range, low end900

Source: Houston Residential Code 2021 §M1503.6 (code trigger) and cross-corroborated range-hood sizing guides, e.g. thetradetable.com (checked Oct 22, 2026).

Sizing a hood to the range, not the cabinet

There’s no single code number for how big a hood should be — code only sets the makeup-air trigger once a hood exceeds 400 cfm. For actual sizing, the common industry rule of thumb is roughly 1 CFM for every 100 BTU of the cooktop’s total rated burner output:

30" gas range
Roughly 300–600 cfm, depending on total burner BTU.
36" gas range
45,000–60,000 BTU typically calls for 450–600 cfm.
48" pro-style range
60,000–90,000 BTU typically calls for 600–900 cfm — already past the code trigger.
60"+ pro-style range
90,000–120,000 BTU typically calls for 900–1,200 cfm.

Any range remodel that steps up to a 48″ or larger pro-style range is very likely to land a hood well above 400 cfm — which is exactly when the makeup-air question in Section M1503.6 needs an answer before the hood goes in, not after.

The duct and damper rules

Compliant Galvanized/stainless/copper duct, own backdraft damper, ends outdoors Violation Shared with another exhaust, or dead-ends in the attic instead
Illustration. A compliant range hood duct is galvanized steel, stainless steel, or copper, carries its own backdraft damper, and runs independently to an outdoor termination — never shared with another exhaust system or dead-ended in the attic.

Sizing the hood correctly solves only part of the code picture. Section M1503.3 requires the duct to have a smooth interior, be airtight, carry its own backdraft damper, and run independent of every other exhaust system in the house — it cannot tie into a bathroom fan or dryer duct. Section M1503.4 adds a material requirement: the duct itself must be galvanized steel, stainless steel, or copper, not flexible foil or plastic ducting sometimes used for other exhausts.

Once a hood crosses the 400 cfm line and the fuel-burning-appliance condition in Section M1503.6 applies, a makeup-air damper has to be added too — either a gravity damper or an electrically operated one that opens automatically whenever the hood runs, per Section M1503.6.2.

Ducted Exhausts air outdoors — triggers §M1503.6 above 400 cfm Recirculating Filters and returns air to the kitchen — no §M1503.6 trigger
Illustration. A ducted hood exhausts air outdoors and can trigger the 400 cfm makeup-air rule; a recirculating hood filters and returns air to the kitchen, so it never triggers that rule — but it also can’t remove combustion byproducts or excess moisture the way a ducted hood can.
  1. 1
    Minimum
    Independent, correctly built duct
    Galvanized steel, stainless steel, or copper; airtight; smooth interior; own backdraft damper; never shared with another exhaust (§M1503.3, §M1503.4).
  2. 2
    Conditional
    Makeup air above 400 cfm
    Required when the hood exceeds 400 cfm and a non-direct-vent fuel-burning appliance sits inside the dwelling’s air barrier (§M1503.6, §M1503.6.2).
  1. 1
    MAV standard
    Size the hood to the range’s BTU output
    MAV sizes the new hood using the cooktop’s actual rated burner output, not a default or a hood that just matches the cabinet opening.
  2. 2
    MAV standard
    Build the duct to code every time
    Correct duct material, its own backdraft damper, and an independent run to an outdoor termination — regardless of CFM.
  3. 3
    MAV standard
    Flag makeup air before the hood goes in
    When a hood crosses 400 cfm, MAV checks the home’s other combustion appliances and adds a makeup-air damper before the hood is installed, not after a backdraft problem shows up.
Questions to ask about a new range hood before a kitchen remodel is finished

Tick each one off as your contractor answers it.

What MAV kitchen-remodel clients say on Google5.0on Google

Verified Google reviews from MAV Design & Build kitchen remodeling clients.

“Love their work, the kitchen turned out amazing and exceeded our expectations and BTW it was completed in much shorter amount of time than I thought it would. Can’t recommend them enough!!”

Aviad · Google review

“I’m extremely satisfied with my kitchen renovation. The entire process was handled with professionalism and precision.”

Waseem Naqvi · Google review

“Great experience working with this company! They remodeled my kitchen and did an amazing job. The team was professional, easy to work with, and always on time.”

Dwight Holden · Google review

“I recently had my kitchen remodeled by this company, and I’m extremely happy with how everything turned out. The cabinets, countertops, and finishes all came together perfectly.”

GIVAONNI B · Google review
Read all reviews on Google →

About MAV Design & Build

Veteran-owned
Licensed and insured Texas general contractor.
Houston-area kitchen remodels
Full kitchen remodeling, from cabinets and countertops to code-compliant range and ventilation work, across MAV’s Houston-area service cities.

Frequently asked questions

At what CFM does a range hood need makeup air in Houston?+
Houston’s 2021 Residential Code, Section M1503.6, sets the trigger at 400 cubic feet per minute: once an exhaust system can move more than 400 cfm, it must be provided with makeup air at a rate approximately equal to the exhaust rate — mechanically or passively.
Does the makeup-air rule apply to every kitchen with a powerful hood?+
As written, Section M1503.6 applies when a gas, liquid, or solid fuel-burning appliance that is neither direct-vent nor mechanically draft-vented is located inside the dwelling’s air barrier — for example, an atmospherically vented gas water heater or furnace inside conditioned space. A hood over 400 cfm in a home where every fuel-burning appliance is sealed-combustion, direct-vent, or outside the air barrier (a garage) does not meet that specific trigger condition on the code’s own text, though it’s still worth confirming case by case before installing a high-CFM hood.
What CFM range hood do I actually need for my range?+
There’s no single code number for sizing — the common industry rule of thumb is roughly 1 CFM per 100 BTU of total burner output. That works out to about 300–600 cfm for a standard 30″ gas range, 450–600 cfm for a 36″ range, 600–900 cfm for a 48″ pro-style range, and 900–1,200 cfm for a 60″ pro-style range — all well past the 400 cfm code trigger.
What are the duct requirements for a range hood?+
Per Section M1503.3, the duct must have a smooth interior surface, be airtight, carry its own backdraft damper, and be independent of every other exhaust system in the house — it cannot share a duct with a bathroom fan or dryer. Section M1503.4 requires the duct itself to be galvanized steel, stainless steel, or copper.
Is there a smaller exception so I don’t need makeup air?+
MAV found one exception in the fetched Houston code text, and it doesn’t apply to a kitchen range hood: Section M1503.6 exempts exhaust systems used exclusively for space cooling that only run with windows or vents already open. A separate, wider exception reported by a secondary summary (around 600 cfm) could not be confirmed against the Houston-specific code text, so it is not stated here.
Does MAV size and vent range hoods to code on a kitchen remodel?+
Yes — on every kitchen remodel, MAV sizes the new range hood to the cooktop’s BTU output, routes the duct to code (own backdraft damper, correct material, independent run to the outdoors), and flags when a makeup-air system is needed before the hood is installed.

Planning a kitchen remodel?

MAV sizes and vents every range hood to code — not just to the bare minimum — as part of every kitchen remodel.

Book a Kitchen Remodel ConsultationCall (832) 532-6829

For the full scope of a kitchen project, see MAV’s kitchen remodeling services overview and the kitchen remodel cost guide. For a related mechanical-ventilation code topic, see bathroom exhaust fan CFM & code rules.

Sources
  1. Houston Residential Code 2021, Chapter 15 — Exhaust Systems (§M1503.3, §M1503.4, §M1503.6, §M1503.6.2)
  2. Range hood CFM sizing guidance (BTU-based rule of thumb, cross-corroborated across multiple industry guides)

Code sections above were checked against the Houston-specific up.codes viewer on October 22, 2026. A secondary “600 cfm exception” claim surfaced by one summarized search result could not be confirmed against the Houston code text and is not stated in this article.

What Houston Homeowners Say⭐ 5.0  •  Google Reviews
Waseem NaqviApril 2026
★★★★★

I'm extremely satisfied with my kitchen renovation. The entire process was handled with professionalism and precision. The crew was respectful, efficient, and always made sure I was informed every step of the way. The final result — a beautiful, well-designed kitchen with top-quality finishes and excellent craftsmanship.

AviadApril 2026
★★★★★

Love their work, the kitchen turned out amazing and exceeded our expectations. Completed in much shorter time than I thought it would. Can't recommend them enough!!

Dwight HoldenMarch 2026
★★★★★

Great experience working with this company! They remodeled my kitchen and did an amazing job. The team was professional, easy to work with, and always on time. Everything went smoothly, and they paid attention to the small details.